Synthes large frag inventory.

Small fragment 310.230 Drill Bit B 2.5 mm, length 180/155 mm, 2-flute, for Quick Coupling Large fragment 310.290 Drill Bit B 3.2 mm, length 195/170 mm, 2-flute, for Quick Coupling Drill with an appropriate drill bit. 6. Determine screw length Instruments Small fragment 319.010 Depth Gauge for Screws B 2.7 to 4.0 mm, measuring range up to 60 mm

Synthes large frag inventory. Things To Know About Synthes large frag inventory.

To fill out the SynForms DHS Inventory, follow these steps: 1. Obtain the SynForms DHS Inventory document from the appropriate source or download it from the designated platform. 2. Read the instructions provided with the form to understand the purpose and specific requirements of the inventory. 3.Large External Fixator—Delta Frame Ankle Bridge Surgical Technique DePuy Synthes 5 RECOMMENDED COMPONENTS FOR BASIC FRAME ProductItem Quantity Number Needed 293.xx 5.0 mm Steinmann Pin, 1 with central thread 294.78x 5.0 mm Self-Drilling 2 Schanz Screw 390.005 Large Combination 2 Clamp 390.008 Large Open Adjustable 2 Clampor LARGE). The purpose of the size specifi c handles for the screwdriver in-serts i.e. the sizes MINI, SMALL and LARGE, is to ensure that the achievable manual torque of the handle is matched to the torque appropriate to the screw size. Instrument set MINI for mini fragment Yellow color-coding Screw diameters 09 - 2. 0 . mmSYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7889-C 2/12 Inventory Control Form Titanium Modular Mini Fragment LCP System 2.0 mm, 2.4 mm and 2.7 mm Instrument and Implant Modules 2.0 mm Titanium Cortex Screws, self-tapping LENGTH LENGTH ...Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010

Additional Info. Unit of Measurement: Each. Catalog Number: 01.111.120. Set includes a variety of instrumentation, K-wires, plates, screws and storage. CLICK HERE for a list of components. Close-up of inner tray and outer tray of 2.0 mm, 2.4 mm and 2.7 mm LCP Modules. Trials available.MODULAR MINI FRAGMENT LCP® SYSTEM 2.0 mm, 2.4 mm and 2.7 mm Implants Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada.Universal Small Fragment System supports insertion of any DePuy Synthes 2.7 mm or 3.5 mm . non-locking LCP ® or VA LCP ® Implant Technology* *pecialized instrumentation used for implants above may be needed. Implants shown above may not be available in all markets.S Contact your local DePuy Synthes representative for more information ...

SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm 211.812 12 mm 211.813 13 ...Keyword Research: People who searched lcp large frag inventory also searched

with protruding screw shaft (large gamefr ) nt 398.651 Pliers for Screw Removal, narrow To remove screws or broken screws with protruding screw shaft or to expose deeper, broken screw shafts (small fragment). The sharp edges of the tip of the pliers act as an awl 399.680 Gouge, width 10 mm, length 205/90 mm To expose the stump of shallow02.130.150, 02.130.150S, 02.130.151... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle Locking Hand System consists of 40 different basic and specialty plates, available in stainless steel and titanium, including fragment-specific plates designed for lateral and dorsal application in fracture repair and deformity correction.Inventory Control Form Large Fragment LCP™ System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. LCPLARGEFRAGICF001v2 07/22 2 *Also available LengthLength 212.215212.201 42 mm 212.216 44 mm 212. ...Fill Synthes Large Frag Inventory, Edit online. Sign, fax and printable from PC, iPad, tablet or mobile with pdfFiller Instantly. Try Now!Fill synthes small frag inventory sites instantly, Edit online. Sign, fax and printable from PC, iPad, tablet or mobile. Try Now! Home; For Business. Enterprise. Organizations. ... synthes large frag inventory. Inventory Control Form Titanium Large Fragment LCP System Patient Information: SYNTHS (USA) To Order: (800) 523-0322 SYNTHS (Canada ...

Sd9ve laser

top with large stop, 150 mm Sizing Template Set 03.111.121S Sizing Template Set for 2.4/2.7 mm VA LCP Two-Column Volar Distal Radius Plate, Extra-long, Sterile Synthes USA, LLC 1101 Synthes Avenue Monument, CO 80132 Manufactured or distributed by: Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA 19380 To order …

The VariAx 2 Small Fragment Platform is designed to offer a comprehensive, modular and easy-to-use platform for treating various small fragment indications including clavicle, humerus, radius, ulna, fibula, fore-/mid and hind foot. Core tray includes one set of T8/T10 screws plus standardized instrumentation and reduction instruments across ...SPONSOR: Synthes (USA) 1690 Russell Road Paoli, PA 19301 (610) 647-9700 ... (USA) Small Fragment DCL System Synthes (USA) Large Fragment DCL System DEVICE DESCRIPTION: The Synthes (USA) 3.5 / 4.5 mm LCP® Metaphyseal Plates are contourable to match the anatomy, have a limited contact design, and are tapered at the plate head. The 3.5 / 4.5 mm ...Get the Synthes Small Fragment Set Inventory Sheet you want. Open it using the cloud-based editor and start altering. Fill the blank fields; concerned parties names, addresses and numbers etc. Customize the blanks with exclusive fillable fields. Put the day/time and place your electronic signature. Click Done after double-checking all the data.Inventory Control Form 4.5 mm VA LCP™ Curved Condylar Plate System with OPTILINK™ Screw Technology Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. Ti/VALCPCC/ICF/V2 04/22 …For larger patients, or when high weight bearing is expected, additional stability can be achieved by adding a carbon fiber rod between the most distal and the most proximal Schanz screw. Product Information. Product Name. Synthes Large External Fixator Set - 115.720. Manufacturer.Universal Small Fragment System • Surgical Technique 3 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures.Wedge fracture control models were tested without the wedge fragment due to a lack of mechanical support. Following initial control testing described below, all specimens were fixed with 1 (transverse fracture model) or 2 (wedge fracture model) 5-hole 2.0 mm MFPs (Synthes, West Chester, Pennsylvania) aligned parallel to the longitudinal bone axis.

3 DePuy Synthes Large External Fixator—Basic Modular Frame Surgical Technique. DePuy Synthes Large External Fixation System. Warning: – DePuy Synthes self-drilling, self-tapping Schanz screws and Steinmann pins are not approved for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic, or lumbar spine.4 Surgical Technique • Large Distractor - Tibia 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures.Large Fragment Locking Compression Plate (LCP. TECHNIQUE GUIDE. Introduction Indications. The Synthes Locking Compression Plates—Narrow and Broad, are intended …DePuy Synthes Reimbursement Support Services is available to help healthcare providers with reimbursement and coding questions. Please see our current reimbursement materials below or reach out to our support service center. 1-800-410-8177 or [email protected]. Reimbursement Specialists are available …Synthes minor frag inventory. Get the up-to-date synthes little frag inventory 2024 now Get Formulare. 4 out of 5. 32 votes. DocHub Berichte. 44 reviews. DocHub Reviews. 23 feedback. 15,005. 10,000,000+ 303. 100,000+ users . Here's how it works. 01. Edit your synthes lcp small frag inventory online.• Small Fragment Standard Instrument Set (103.501) • Small Fragment Standard Screw Set ... • Large core diameter provides improved bending and shear strength ... Screws Bibliography: 1. DePuy Synthes StarDrive vs Hex Static Torsion Test. 2011. #SET_20110610. Screw Reference Chart Thread Diameter 2.7 mm 3.5 mm 4.0 mm Screw Type Cortex ...

of threads into far bone fragment, for greater interfragmentary compression • Cancellous thread profile uses deep cutting threads with a large pitch to increase resistance to pullout. The large pitch also accelerates screw insertion and removal • Self-drilling, self-tapping screw tip facilitates screw insertion by eliminating

Inventory Control Form Variable Angle Locking Hand System Titanium 1.3 mm Titanium Locking Plates* 04.130.150 Straight Plate, 6 holes 04.130.151 Straight Plate, 12 holes 04.130.152 T-Plate, 3 holes head, 5 holes shaft 04.130.153 Y-Plate, 3 holes head, 5 holes shaft 04.130.154 Phalangeal Base Plate, 2 holes head, 5 holes shaft® 2 Mini Fragment system set overview MiniFrag: tray layout A Top Layer: VariAx 2 Instruments • T8 specific instruments (Drills, Drill Guide, Joystick, Screwdriver) • General instruments (Handle, Depth Gauge, Bending tools etc) 1 Drawer: T8 Screws & Plates • 2.7mm Screws (Locking & Non-Locking) • 2.4mm Screws (Locking & Non-Locking)In today’s fast-paced business environment, effective inventory management is crucial for the success of any organization. One of the primary reasons why inventory management is es...Handy tips for filling out Synthes small frag inventory online. Printing and scanning is no longer the best way to manage documents. Go digital and save time with signNow, the best solution for electronic signatures.Use its powerful functionality with a simple-to-use intuitive interface to fill out Synthes large frag inventory online, e-sign them, and quickly share …Inventory Control Form Variable Angle LCP Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column Shaft Holes Length (mm) Angled 02.115.630 3 41 +90° 02.115.631 3 41 –90° 02.115.640 4 49 +90° 02.115.641 4 49 –90° 2.4 mm VA LCP Dorsal Distal Radius L-Plate, 2 holes headInventory Control Form Titanium Locking Periarticular Plating System 14 mm 16 mm 414.818 18 mm 20 mm 414.822 22 mm 414.824 24 mm 414.826 26 mm 28 mm 30 mm 414.832 32 mm 34 mm 414.836 36 mm 414.838 38 mm 40 mm 414.842 42 mm 414.844 44 mm Length 65 mm 04.205.070 70 mm 04.205.075 75 mm 04.205.080 80 mm 85 mm 90 mm 04.205.095 95 mm Length 04.205. ...INVENTORY CONTROL FORM 2.4 mm LCP ® Distal Radius Plate System 2.4 mm Locking Screws, self-tapping, T8 STARDRIVE TM Screwdriver Recess 2.4 mm Cortex Screws, self-tapping, T8 STARDRIVE Screwdriver Recess 2.7 mm Cortex Screws, self-tapping, T8 STARDRIVE Screwdriver Recess LENGTH 212.806 6 mm 212.808 8 mm 212.810 10 …4 DePuy Synthes 4.5 mm LCP® Proximal Femur Plates Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, whichInventory Control Form QIS AND 2.0 MM CANNULATED SCREW SYSTEM PLUS (CSS+) Head Height: 1.65 mm Washer and Head Construct Height: 1.44 mm Thread Length Short Thread: approx. 25% Total Length or 4 mm Long Thread: approx. 40% Total Length Thread Length Head Height Construct Height Length Washers Part Number 04.353.900.05 …Product Overview. The ANTHEM® Mini Fragment Fracture System provides intraoperative versatility to treat a variety of traumatic fractures. The comprehensive set featuring multiple implant options and innovative instruments offers system efficiency and procedural ease. 1+.

Critical examination crossword clue

In today’s fast-paced business environment, effective inventory management is crucial for the success of any organization. One of the primary reasons why inventory management is es...

Now, working with a Synthes Inventory Control Form requires a maximum of 5 minutes. Our state web-based blanks and clear guidelines eliminate human-prone errors. Adhere to our easy steps to get your Synthes Inventory Control Form well prepared quickly: Choose the web sample in the catalogue. Type all necessary information in the necessary ...Understanding how the MMPI is used to help mental health professionals evaluate and diagnose mental health conditions may help you identify its benefits. Does taking a personality ...2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.LC-DCP SYNTHES Small Fragment Set Titanium LC DCP. Synthes. $2,950.00. SYNTHES MAXILLOFACIAL CRANIOFACIAL MODULAR FIXATION SYSTEM 1.3mm CRANIAL MODULE. Synthes. Sold out. SYNTHES 4.0 MM Cannulated Screw Set Orthopedic Surgery 4mm. Synthes. $1,490.00.6 DePuy Synthes 3.5 mm LCP® Proximal Tibia Plates Surgical Technique Preparation 1 Preparation Required set 105.434 Small Fragment LCP Instrument and Implant Set, with self-tapping screws or 145.434 Small Fragment LCP Instrument and Titanium Implant Set, with self-tapping screws Optional sets 115.700 Large Distractor Set6 DePuy Synthes 3.5 mm LCP® Proximal Tibia Plates Surgical Technique Preparation 1 Preparation Required set 105.434 Small Fragment LCP Instrument and Implant Set, with self-tapping screws or 145.434 Small Fragment LCP Instrument and Titanium Implant Set, with self-tapping screws Optional sets 115.700 Large Distractor SetSynthes Large Fragment Locking Com-pression Plate (LCP) Technique Guide (036.000.019). LCP Condylar Plate 4.5/5.0 The LCP Condylar Plate 4.5/5.0 System has many similarities to traditional plate fixation methods, with a few important improvements. The technical innova-tion of locking screws provides the abil-ity to create a fixed-angle constructSynthes (USA) Large Fragment LCP System T Plates Device Description: The Synthes 3.5mm LCP Posteromedial Proximal Tibia Plates are pre-contoured bone fixation plates intended for the treatment of fractures of the tibia. The plates are offered sterile and non-sterile and are available in stainless steel and titanium. ... DePuy Synthes Large Fragment Locking Compression Plate (LCP) Technique Guide. The 4.5 mm LCP Condylar Plate System has many similarities to traditional plate fixation methods, with a few important improvements. The technical innovation of locking screws provides the ability to create a fixed-angle construct while The DePuy Synthes Vet Large Fragment System is part of a stainless-steel plate and screw system that merges locking screw technology with conventional plating techniques. This system contains the 4.5mm – 5.5mm implants and related instruments required for LC-DCP ®, DCP ® and LCP ® Plating. The Large Fragment System provides the most ... The Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant. Features. Specially large bends provide optimal guidance through the soft tissues. Can be used even in adipose patients. Ball tips allow a secure hold in the bone despite minimal contact. Threaded pin for secure and continu-ously adjustable locking of the for-ceps. Spiked disk that can be placed onto the tips permits use even in poor bone quality.

DESCRIPTION. Our LCP™ Curved Locking Compression Plates are part of the DePuy Synthes Trauma LCP™ Locking Compression Plate System. This stainless steel and titanium plate screw system merges locking screw technology with conventional plating techniques for use in various orthopaedic trauma applications. Get in Touch with a Sales Consultant.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 02.107.202 2 holes ...Universal Small Fragment System • Surgical Technique 3 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures.Instagram:https://instagram. friendswood tx power outage EVOS SMALL Resources. Catalog excerpts. Simply advanced The EVOS SMALL Plating System takes an evolutionary approach to simplifying and unifying small fragment plating systems. www.EVOSsmall.com smith&nephew EVOS SMALL Plating System Supporting healthcare professionals. Open the catalog to page 1. Trauma surgery is challenging and ever-changing.Synthes 3. The Combi-hole. The LCP (Locking Compression Plate) system offers the surgeon the choice, preoperatively and intraoperatively, of using either standard screws or locking screws - or a combination of the two screw types - for fracture fixation. Experience in the use of LC-DCP or DCP plates or instruction by a surgeon with ... duda ruck dundalk obituaries Unit of Measurement: Each. Catalog Number: 105.434. Set includes an assortment of instrumentation, implants and storage. CLICK HERE for a full list of set contents. Small Fragment Set Screw Pack shown below. LCP Plates shown below. Trials available. Photo is representative—please contact your sales rep for more complete details. osrs foresters ratio %PDF-1.4 %âãÏÓ 919 0 obj > endobj xref 919 59 0000000016 00000 n 0000002072 00000 n 0000002231 00000 n 0000003394 00000 n 0000003956 00000 n 0000004490 00000 n 0000004981 00000 n 0000005158 00000 n 0000005347 00000 n 0000005459 00000 n 0000005573 00000 n 0000005686 00000 n 0000005775 00000 n 0000006250 00000 n 0000006805 00000 n 0000007265 00000 n 0000007809 00000 n 0000008211 00000 n ... 1.5 mm LCP® Modular Mini Fragment System. 1.5 mm instrument and implant modules. The 1.5 mm LCP® Modular Mini Fragment System consists of 1.5 mm Locking Compression Plate (LCP) Instrument and Implant Module Sets. Plates – Low profile designed to help minimize soft tissue irritation – Cut-to-length feature minimizes inventory qpublic mcdonough ga The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who hassynthes large frag inventory Inventory Control Form Titanium Large Fragment LCP System Patient Information: SYNTHS (USA) To Order: (800) 523-0322 SYNTHS (Canada) Ltd. To Order: (800) hariyama gen 3 learnset synthes.vo.llnwd.net food lion hours woodbridge va 02.118.408 7 holes, right 02.118.409 7 holes, left. 2.7 mm Variable Angle LCP Distal Tibia T-Plates. 02.118.306 4 holes 02.118.307 6 holes. Available nonsterile or sterile-packed. Add "S" to catalog number to order sterile product. Inventory Control Form. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System.Like the weather, the housing market usually cools in the fall. Will the coronavirus make this year different? By clicking "TRY IT", I agree to receive newsletters and promotions f... stauffers rohrerstown rd Plates for the Small Fragment LCP. ®System. (continued) LCP®One-Third Tubular Plates, with collar*. • Available with 3-10 holes (33 mm-117 mm lengths) and 12 holes (141 mm) • Plate contains only locking holes, that accept 3.5 mm locking screws, 3.5 mm cortex screws, and 2.7 mm cortex screws.510 (k) Number. K160553. Device Name. DePuy Synthes 4.0 mm and 5.0 mm Locking Screws - MR Conditional, DePuy Synthes Wrist Fusion Plate (WFP) - MR Conditional, DePuy Synthes Large Fragment Dynamic Compression Locking (DCL) System -MR Conditional, DePuy Synthes Small Fragment Dynamic Compression Locking (DCL) System - MR Conditional, De. dance clubs san bernardino DESCRIPTION. Our LCP™ Curved Locking Compression Plates are part of the DePuy Synthes Trauma LCP™ Locking Compression Plate System. This stainless steel and titanium plate screw system merges locking screw technology with conventional plating techniques for use in various orthopaedic trauma applications. Get in Touch with a Sales Consultant.Follow these simple instructions to get Synthes Mini Frag Inventory completely ready for submitting: Select the document you require in the library of templates. Open the document in the online editing tool. Go through the recommendations to determine which details you need to include. Choose the fillable fields and include the requested info. finese2tymes 4 DePuy Synthes 4.5 mm LCP® Proximal Tibia Plates Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant. amanda renner legs About This Product. The DePuy Synthes Distal Femur System consists of LCP Distal Femur Plates and different type of Screws used with the plate such as. Locking Screw. Cortex Screw. Screw Hole Insert. Get in Touch with a Sales Consultant. march weather santa fe Using our solution filling exit Synthes Small Frag Lcp Inventory Control Form just takes one matter of minutes. We make that possible by offering you zugang till our full-fledged editor capable of altering/correcting a document?s original textual content, addition unique area, and putting your signature on.About This Product. The DePuy Synthes Distal Femur System consists of LCP Distal Femur Plates and different type of Screws used with the plate such as. Locking Screw. Cortex Screw. Screw Hole Insert. Get in Touch with a Sales Consultant.Orthopaedic Cable System. The DePuy Synthes Cable System is a cerclage system that consists of two different-sized cerclage cables with crimp in three different materials [Stainless steel, Titanium Alloy, Cobalt Chromium Alloy], and instruments for applying the cable assembly. Product Specifications.